Home » Projects »

Forensic Analysis of Subsurface Vapor Intrusion to Indoor Air and Background Conditions at a Former MGP Site in New Jersey

Forensic Analysis of Subsurface Vapor Intrusion to Indoor Air and Background Conditions at a Former MGP Site in New Jersey

Client

Jersey Central Power & Light Company

Services Provided

Subslab Sampling; Indoor and Outdoor Air Sampling; Risk Assessment; Forensic Analysis; Regulation Liaison

A variety of scientific instruments, gas canisters, gauges, meters, and tubing are laid out on a concrete surface, with a person adjusting equipment in the background.

Location

Newton, New Jersey, USA

Project Practice Areas

Contaminated Sites, Air Quality

Type of Facility

Former MGP Site

Project Specifics

A former manufactured gas plant (MGP) site was redeveloped into a multi-unit commercial plaza, and an assessment of the potential for subsurface vapor intrusion to indoor air was required to comply with new Guidance from the New Jersey Department of Environmental Protection (NJDEP). The various businesses located with the commercial plaza included a hardware store, restaurant, and beauty salon, all of which were expected to have interior sources of various chemical vapors. In addition, outdoor air in parts of New Jersey occasionally exceeds the target concentrations for benzene, which is an expected constituent of MGP wastes. In order to comply with the NJDEP Guidance, without erroneously attributing background contributions to subsurface vapor sources, Geosyntec designed an investigative program and conducted forensic analysis of the data to distinguish the relative contributions of subsurface, interior and outdoor sources to indoor air vapor concentrations.

Geosyntec Scope of Services

Geosyntec was retained to design, and interpret data collected from, an investigation of the potential for vapor intrusion. The study consisted of multi-level soil gas sampling, indoor air monitoring during and outside of business hours, and outdoor air quality monitoring. Consumer products and outdoor air contamination were the dominant sources of 40 detectable VOCs in indoor air, 14 of which were detected at concentrations above risk-based criteria. Some compounds detected in indoor air samples are also constituents of MGP wastes, including benzene and naphthalene, so a forensic analysis was necessary to determine the relative proportion from subsurface and background sources. The forensic analysis included graphical presentations of compound ratios, spatial and temporal trends, comparisons to typical background levels, and multi-component analyses.

Notable Accomplishments

Geosyntec prepared a report with a detailed forensic analysis to demonstrate that the primary source of the chemicals in indoor air was interior sources, occupant’s activities and outdoor air quality. The contribution from subsurface MGP materials was negligible compared to background sources, and posed no significant health risk. NJDEP concurred with Geosyntec’s analysis, and required only confirmatory monitoring.